P16DC
DTC P16DC: Electric Vacuum Pump Relay 2 Stuck ON1. Turn the ignition switch OFF.
2. Remove electric vacuum pump relay 2, and check the relay.
Is electric vacuum pump relay 2 OK?
YES-Go to step 3.
NO-Replace electric vacuum pump relay 2.
3. Remove the No. 17 (15 A) fuse in the under-hood fuse/relay box.
4. Disconnect the electric vacuum pump 2P connector.
5. Check for continuity between electric vacuum pump relay 2 terminals No. 1 and No. 2.
Is there continuity?
YES-Repair short in the wires between electric vacuum pump relay 2 (+B line) and (pump motor line).
NO-Go to step 6.
6. Short the SCS line with the HDS.
7. Disconnect PCM connector A (44P).
8. Turn the ignition switch ON (II).
9. Measure the voltage between body ground and PCM connector A, (44P) terminal No. 12.
Is there any voltage?
YES-Repair short to power in the wire between the electric vacuum pump relay 1/2 and the PCM.
NO-Update the PCM if it does not have the latest software, or substitute a known-good PCM, then go to step 1 and recheck. If no DTCs are indicated, and the PCM was substituted, replace the original PCM.