Operation CHARM: Car repair manuals for everyone.

Symptom Troubleshooting Information

Symptom Troubleshooting Information

General Check before Troubleshooting

Before troubleshooting the immobilizer system, check the following general items and solve any if applicable:

- The battery is low; charge the battery fully, then troubleshoot the immobilizer system.
- The ignition key is not a genuine Acura part; use the Acura-approved key blank, register the key, then troubleshoot the immobilizer system.
- A key ring, keys, or a key case is used; remove the key from it, and troubleshoot the immobilizer system with a key only.
- An aftermarket electrical part is attached; remove it, then troubleshoot the immobilizer system.

Symptom Troubleshooting Using the Immobilizer Indicator Lighting Pattern

The pattern of the immobilizer indicator light can help troubleshoot the condition of the immobilizer system. Following are descriptions of the four possible patterns.

Normal operation

If the immobilizer code is identified, the immobilizer indicator quickly flashes once when the ignition switch is turned ON (II).

The immobilizer indicator does not come on when the ignition switch is turned OFF.

Immobilizer code is not identified

If the immobilizer code is not identified, the immobilizer indicator will quickly flash once, then will blink until the ignition switch is turned OFF. When the ignition switch is turned OFF, the indicator will blink ten times, then go off. The state of the immobilizer key registration and the IMOCD line can be checked by going into a SYSTEM CHECK and STATUS LOG with the HDS

Immobilizer indicator does not come on

If the immobilizer indicator does not come on after turning the ignition switch ON (II), an open or short in the F-CAN lines between the PCM and the gauge control module. Watch the malfunction indicator lamp (MIL). If the MIL stays on, go to the PGM-FI system troubleshooting.

Immobilizer indicator does not go off

If the immobilizer indicator does not go off after turning the ignition switch ON (II), do the gauge control module self-diagnostic function. If the indicator drive circuit is OK, do the SYSTEM CHECK and STATUS LOG with the HDS.

Symptom Troubleshooting Using Malfunctioning Circuit Functions

If a malfunction occurs in the immobilizer circuit, use the table to cross-reference the malfunctioning function to the line(s) that should be checked:






System Check and Status Log

NOTE: The HDS can be used to:

- Check the state of the immobilizer key registration and the IMOCD line by doing a SYSTEM CHECK.

1. Connect the HDS to the data link connector, then turn the ignition switch ON (II) and follow the prompts to the MAIN MENU.

NOTE: If the HDS does not communicate with the vehicle, go to the DLC circuit troubleshooting in Computers and Control Systems.

2. At the MAIN MENU, enter IMMOBILIZER, then select the IMMOBILIZER SETUP.
3. Do the SYSTEM CHECK. If there is a system check number, do the troubleshooting for the item indicated.
4. Check the status log using the HDS. Troubleshoot the line with the highest counts. If all the lines are "0" zero, the problem may not be caused by the immobilizer system, check for ignition or fuel problems.

NOTE: Once repaired, clear the status log by removing the No. 23 (10 A) fuse in the under-hood fuse/relay box or unplugging the immobilizer-keyless control unit.