The A/C Compressor Clutch and the A/C Condenser/Radiator Fans Are Inoperative, But the Blower and Heater Controls Work
The A/C compressor clutch and the A/C condenser/radiator fans are inoperative, but the blower and heater controls work
Probable cause: A/C pressure sensor circuit and A/C signal circuit malfunction
Do the A/C signal circuit troubleshooting A/C Signal Circuit Troubleshooting
Troubleshoot the A/C pressure sensor circuit
NOTE: The A/C pressure sensor can malfunction without setting a DTC
Also check for
HVAC DTCs Initial Inspection and Diagnostic Overview
Also check for
Powertrain DTCs Initial Inspection and Diagnostic Overview
Also check for
Poor or loose connections at the terminals