Operation CHARM: Car repair manuals for everyone.

Entry Lights Control System (MICU) Input Test




Entry Lights Control System (MICU) Input Test

1. Check the No. 10 (7.5 A) fuse in the under-dash fuse/relay box. If any fuse is blown, replace it and go to step 2.

2. Disconnect under-dash fuse/relay box connectors E, F, K, R, and T.

NOTE: All connector views are shown from wire side of female terminals.










3. Inspect the connector and socket terminals to be sure they are all making good contact.

- If the terminals are bent, loose or corroded, repair them as necessary and recheck the system.
- If the terminals look OK, go to step 4.

4. With the connectors still disconnected, do these input tests at the following connector.

- If any test indicates a problem, find and correct the cause, then recheck the system.
- If all the input tests prove OK, go to step 5.





5. Reconnect the connectors to the under-dash fuse/relay box, turn the ignition switch to ON (II), and do these input tests at the following connectors.

- If any test indicates a problem, find and correct the cause, then recheck the system.
- If all the input tests prove OK, the MICU must be faulty; replace the under-dash fuse/relay box Under-Dash Fuse/Relay Box Removal/Installation.