Solar Sensor: Testing and Inspection
Sunlight Sensor Test
NOTE: Before testing the sensor, check for climate control DTCs Initial Inspection and Diagnostic Overview.
1. Pull out the sunlight sensor from the dashboard.
2. Turn the ignition switch to ON (II). Measure the voltage between the terminals with the (+) probe on terminal No. 4 and the (-) probe on terminal No. 2 with the connector connected.
NOTE: The voltage readings will not change under the light of a flashlight or a fluorescent lamp.
Voltage should be:
- 3.6-3.7 V or more with the sensor out of direct sunlight.
- 3.3-3.5 V or less with the sensor in direct sunlight.
3. If the voltage is not as specified, replace the sunlight sensor Service and Repair.