Failure Mode G
Mode G: SRS Unit ground and component ground open.
CAUTION : Disconnect both the negative and positive battery cables. Connect the short connector to the airbag assembly - refer to "Indicator Light Troubleshooting", caution notice.
1. Connect the SRS test harness B to the main harness's 12-P connector. Check for continuity between the B8, B9 terminal and ground.
- If there is continuity, the SRS unit is faulty; replace and recheck the voltages according to the chart in the "Indicator Stays On Continuously" procedure.
- If there is no continuity, SRS unit ground the control unit component grounds or the main harness is faulty; check the ground (Check wire and control unit mount bolts.) and, if necessary, replace the main harness and recheck the voltages according to the chart in the "Indicator Stays On Continuously" procedure.