Service Specifications

Standard
Each rod falls into one of four tolerance ranges, from 0 to 0.24 mm in inccreaments of 0.006 mm, depending on large end diameter. The rods are then stamped with Number or bar 1, 2, 3, or 4 indicating the range.
Limit
Bolt Torque
Standard Diameter
0.15-0.30 Millimeter (mm)
0.40 Millimeter (mm)
46 Newton Meter (Nm)
51.0 Millimeter (mm)
0.021-0.049 Millimeter (mm)
0.06 Millimeter (mm)