Operation CHARM: Car repair manuals for everyone.

Keyless Entry Module: Testing and Inspection

1. Remove the glove box.
2. Disconnect the 18P connector from the control unit.

Control Unit Input Test (With Keyless Entry):




3. Inspect the connector and socket terminals to be sure they are all making good contact.
^ If the terminals are bent, loose or corroded, repair them as necessary, and recheck the system.
^ If the terminals look OK, make the following input tests at the connector.
- If any test indicates a problem, find and correct the cause, then recheck the system.
- If all the input tests prove OK, the control unit must be faulty; replace it

Control Unit Input Test (With Keyless Entry):




CAUTION: To prevent damage to the motor, apply battery voltage only momentarily.