Spring-Loaded Lock Connector
Some SRS system connectors have a spring-loaded lock.Disconnecting
1. To release the lock, pull the spring-loaded sleeve toward the stop while holding the opposite half of the connector.
2. Then pull the connector halves apart.
NOTE: Be sure to pull on the sleeve and not on the connector half.
Connecting
1. Hold the pawl-side connector half, and press on the back of the sleeve-side connector half in the direction shown. As the two connector halves are pressed together, the sleeve is pushed back by the pawl.
2. When the connector halves are completely connected, the pawl is released, and the spring-loaded sleeve locks the connector.