Wiper Relay: Testing and Inspection
Power Relay TestUse the chart to identify the type of relay, then do the test listed for it.
NOTE: The turn signal/hazard relay input test
Five-terminal type A:
Check for continuity between the terminals.
- There should be continuity between the No. 1 and No. 2 terminals when power and ground are connected to the No. 3 and No. 5 terminals.
- There should be continuity between the No. 2 and No. 4 terminals when power is disconnected.