Dome Lamp: Testing and Inspection
Ceiling Light Test1. Turn the light switch OFF.
2. Carefully pry off the lens (A) with a small screwdriver.
CEILING LIGHT: 7W
3. Remove the two mounting nuts.
4. Disconnect the 3P connector (B) from the housing (C).
5. Check for continuity between the terminals in each switch position according to the table.
6. If the continuity is not as specified, check the bulbs (D).
If the bulbs are OK, replace the light.