Starter Solenoid: Testing and Inspection
Starter Solenoid Test1. Check the hold-in coil for continuity between the S terminal (A) and the armature housing (ground). There should be continuity.
- If there is continuity, go to step 2.
- If there is no continuity, replace the solenoid.
2. Check the pull-in coil for continuity between the S terminal (A) and M terminal (B). There should be continuity.
- If there is continuity, the solenoid is OK.
- If there is no continuity, replace the solenoid.