Power Mirror Motor: Testing and Inspection
Power Mirror Actuator TestNOTE: The power mirror actuator can be tested by using the HDS by following these steps:
- Select BODY ELECTRICAL from the SYSTEM SELECTION MENU.
- Select FUNCTION TESTS, and then the appropriate power mirror function test.
1. Remove the door panel.
2. Disconnect the 13P connector (A) from the power mirror actuator (B).
3. Check actuator operation by connecting power and ground according to the table.
4. If the mirror fails to work properly, replace the mirror actuator.
Defogger Test
5. Check for continuity between the No. 5 and No. 4 terminals of the 13P connector. There should be continuity with the defogger switch ON. If there is no continuity, check for an open circuit.