Select Arm Clearance Inspection
Select Arm Clearance Inspection1. Measure the clearance between the select arm (A) and interlock (B) with a feeler gauge (C). if the clearance is more than the service limit, go to step 2.
Standard: 0.05 - 0.25 mm (0.002 - 0.010 inch)
Service Limit: 0.5 mm (0.020 inch)
2. Measure the width of the select arm.
- If the width is not within the standard, replace the select arm.
- If the width is within the standard, replace the interlock.
Standard: 12.9 - 13.0 mm (0.50 - 0.51 inch)