How to Troubleshoot Circuits at the ECM
How to Troubleshoot Circuits at the ECMSpecial Tools Required
Backprobe set 07SAZ-001000A (2 required)
1. Connect the backprobe adapters (A) to the stacking patch cords (B), and connect the cords to a digital multimeter (C).
2. Using the wire insulation as a guide for the contoured tip of the backprobe adapter, gently slide the tip into the connector from the wire side until it touches the end of the wire terminal.