Pressure Plate
Pressure plateWarpage
Standard or New 0.08 mm (0.003 inch) maximum
Service Limit 0.15 mm (0.006 inch)
Height of diaphragm spring fingers measured with special tool and feeler gauge
Standard or New 0.6 mm (0.02 inch) maximum
Service Limit 0.8 mm (0.03 inch)
Torque the mounting bolts in a crisscross pattern. Tighten the bolts in several steps to prevent warping the diaphragm spring.
PRESSURE PLATE MOUNTING BOLT TORQUE, 25 Nm (2.6 kgf-m, 19 ft. lbs.)