Operation CHARM: Car repair manuals for everyone.

B1241

DTC B1241 or Blower motor lock is indicated.:
A Problem in the Blower Motor Circuit

1. Clear the DTC with the HDS.
2. Operate the climate control system in several modes.
3. Check for DTCs using the HDS or self-diagnostic.

Is DTC B1241 or Blower motor lock indicated?

YES - Go to step 4.

NO - Intermittent failure, check for loose wires or poor connections on the blower motor circuit.

4. Turn the ignition switch OFF.
5. Check the No. 21 (40 A) fuse in the under-hood fuse/relay box, and the No. 30 (7.5 A) fuse in the driver's under-dash fuse/relay box.

Are the fuses OK?

YES - Go to step 6.

NO - Replace the fuse(s), and recheck. If the fuses blow again, check for a short in the No. 21 (40 A) and No. 30 (7.5 A) fuses circuit.




6. Connect the No. 2 terminal of the blower motor 2P connector to body ground with a jumper wire.
7. Turn the ignition switch ON (II).

Does the blower motor run?

YES - Go to step 8.

NO - Go to step 23.

8. Turn the ignition switch OFF.
9. Disconnect the jumper wire.
10. Disconnect the power transistor 5P connector.




11. Check for continuity between the No. 5 terminal of the power transistor 5P connector and body ground.

Is there continuity?

YES - Go to step 12.

NO - Check for an open in the wire between the power transistor and body ground. If the wire is OK, check for poor ground at G506.




12. Connect the No. 4 and No. 5 terminals of the power transistor 5P connector with a jumper wire.
13. Turn the ignition switch ON (II).

Does the blower motor run at high speed?

YES - Go to step 14.

NO - Repair open in the BLU/RED wire between the power transistor and the blower motor.

14. Turn the ignition switch OFF.
15. Disconnect the jumper wire.
16. Disconnect the climate control unit 40P connector.




17. Check for continuity between the No. 9 and No. 10 terminals of the climate control unit 40P connector and body ground individually.

Is there continuity?

YES - Repair any short to body ground in the wire(s) between the climate control unit and the power transistor.

NO - Go to step 18.




18. Check for continuity between the given terminals of the climate control unit 40P connector and the power transistor 5P connector.

Is there continuity?

YES - Go to step 19.

NO - Repair any open in the wire(s) between the climate control unit and the power transistor.

19. Start the engine.




20. Check for voltage between the No. 9 and No. 10 terminals of the climate control unit 40P connector and body ground individually.

Is there voltage?

YES - Repair short to power in the wires.

NO - Go to step 21.

21. Reconnect the climate control unit 40P connector.
22. Test the power transistor.

Is the power transistor OK ?

YES - Check for loose wires or poor connections at the climate control unit 40P connector and at the power transistor 5P connector. If the connections are good, substitute a known-good climate control unit, and recheck. If the symptom/indication goes away, replace the original climate control unit.

NO - Replace the power transistor.

23. Disconnect the jumper wire.
24. Disconnect the blower motor 2P connector.




25. Measure the voltage between the No. 1 terminal of the blower motor 2P connector and body ground.

Is there battery voltage?

YES - Replace the blower motor.

NO - Go to step 26.

26. Turn the ignition switch OFF.
27. Remove the blower motor relay from the under-hood fuse/relay box, and test it.

Is the relay OK?

YES - Go to step 28.

NO - Replace the blower motor relay.




28. Measure the voltage between the No. 2 terminal of the blower motor relay 4P socket and body ground.

Is there battery voltage?

YES - Go to step 29.

NO - Replace the under-hood fuse/relay box.

29. Turn the ignition switch ON (II).




30. Measure the voltage between the No. 4 terminal of the blower motor relay 4P socket and body ground.

Is there battery voltage?

YES - Go to step 31.

NO - Repair open in the wire between the No. 30 fuse in the driver's under-dash fuse/relay box and the blower motor relay.

31. Turn the ignition switch OFF.




32. Check for continuity between the No. 3 terminal of the blower motor relay 4P socket and body ground.

Is there continuity?

YES - Repair open in the WHT wire between the blower motor relay and the blower motor.

NO - Check for an open in the wire between the blower motor relay and body ground. If the wire is OK, check for poor ground at G301.