Operation CHARM: Car repair manuals for everyone.

Advanced Diagnostics

DTC P2610: Powertrain Control Module (PCM) Internal Power Off Timer Malfunction




General Description
The powertrain control module (PCM) has a built-in power off timer that measures the duration of time the ignition switch is off. This measurement is used for evaporative emission (EVAP) leak detection and temperature assumption of the catalytic converter.

The CPU in the PCM accesses the power off timer when reading the measured duration. When the access process fails, a malfunction is detected and a DTC is stored. When an abnormality is found in the read data, a malfunction is detected and a DTC is stored.




Monitor Execution, Sequence, Duration, DTC Type, OBD Status




Enable Conditions

Malfunction Threshold
The access process to the power off timer fails, or a malfunction is found in the read data for at least 10 seconds.

Diagnosis Details

Conditions for illuminating the MIL
When a malfunction is detected, the MIL comes on and the DTC and the freeze frame data are stored in the PCM memory.

Conditions for clearing the MIL
The MIL will be cleared if the malfunction does not recur during three consecutive trips in which the diagnostic runs.

The MIL, the DTC, and the freeze frame data can be cleared by using the scan tool Clear command or by disconnecting the battery.