DTC P0141: Secondary Heated Oxygen Sensor (Secondary HO2S (Sensor 2)) Heater Circuit MalfunctionGeneral Description
A heater for the zirconia element is embedded in the secondary heated oxygen sensor (secondary HO2S), and it is controlled by the engine control module (ECM)/powertrain control module (PCM). When activated, it heats the sensor to stabilize and speed up the detection of oxygen content when the exhaust gas temperature is cold.
If the secondary HO2S heater draws no more, or no less than a specified amperage, the ECM/PCM detects a malfunction and a DTC is stored.
Monitor Execution, Sequence, Duration, DTC Type, OBD Status
Enable Conditions
Malfunction Threshold
The current is 0.38 A or less, or 3.33 A or more, for at least 5 seconds when the heater is on.
Driving Pattern
Start the engine. Hold the engine speed at 3,000 rpm without load (in Park or neutral) until the radiator fan comes on.
Diagnosis Details
Conditions for illuminating the MIL
When a malfunction is detected, the MIL comes on and the DTC and the freeze frame data are stored in the ECM/PCM memory.
Conditions for clearing the MIL
The MIL will be cleared if the malfunction does not recur during three consecutive trips in which the diagnostic runs.
The MIL, the DTC, and the freeze frame data can be cleared by using the scan tool Clear command or by disconnecting the battery.