3. Change Lever Clearance Inspection
Change Lever Clearance Inspection1. Measure the clearance between the change lever (A) and the select lever (B) with a feeler gauge (C). If the clearance is more than the service limit, go to step 2.
2. Measure the groove of the change lever.
- If the groove is not within the standard, replace the change lever.