A/C Condenser Fan Circuit Troubleshooting (Short)
A/C Condenser Fan Circuit Troubleshooting (Short)NOTE: A short in the A/C condenser fan circuit causes the fan to run constantly whenever the ignition switch is ON (II).
1. Disconnect the A/C condenser fan motor 2P connector from the radiator fan control (RFC) unit.
2. Check for continuity between A/C condenser fan motor 2P connector terminal No. 2 and body ground.
Is there continuity?
YES - Repair short in the wire between A/C condenser fan motor 2P connector terminal No. 2 and body ground.
NO - Replace the RFC unit.