DTC 32-3x
DTC 32-3x ("x" can be 0 thru 9 or A thru F): Short to Another Wire or Decreased Resistance in Front Passenger's Side Airbag InflatorSpecial Tools Required
- SRS inflator simulator 07SAZ-TB4011A
- SRS simulator lead E 07XAZ-S1A0200
- SRS short canceller 070AZ-SAA0100
NOTE: Before doing this troubleshooting procedure, review SRS Precautions and Procedures and General Troubleshooting Information.
1. Clear the DTC memory.
2. Turn the ignition switch ON (II), and check that the SRS indicator comes on for about 6 seconds and then goes off.
Does the SRS indicator stay on, and is DTC 32-3x indicated?
YES - Go to step 3.
NO - Intermittent failure, system is OK at this time. Go to Troubleshooting Intermittent Failures. Troubleshooting Intermittent Failures If another DTC is indicated, troubleshoot the DTC.
3. Turn the ignition switch OFF. Disconnect the negative cable from the battery, then wait for 3 minutes.
4. Disconnect the floor wire harness 2P connector (A) from the front passenger's side airbag (B).
5. Connect the SRS inflator simulator (2 ohms connector) and simulator lead E to the floor wire harness.
6. Reconnect the negative cable to the battery.
7. Clear the DTC memory.
8. Read the DTC.
Is DTC 32-3x indicated?
YES - Go to step 9.
NO - Short to another wire in the front passenger's side airbag inflator; replace the front passenger's side airbag.
9. Turn the ignition switch OFF. Disconnect the negative cable from the battery, then wait for 3 minutes.
10. Disconnect SRS unit connector B (28P) from the SRS unit.
11. Disconnect the SRS inflator simulator from the SRS simulator lead. Do not disconnect the simulator lead from the floor wire harness 2P connector.
12. Connect the SRS short canceller (070AZ-SAA0100) to the No. 23 and No. 24 terminals of SRS unit connector B (28P).
13. Measure the resistance between the terminals of the SRS simulator lead. There should be an open circuit (ohmmeter reads OL) or at least 1 Mohm.
Is the resistance as specified?
YES - Faulty SRS unit or poor connection at SRS unit connector B (28P) and the SRS unit. Check the connection; if the connection is OK, replace the SRS unit.
NO - Short in the floor wire harness; replace the floor wire harness.