Connecting Rod: Testing and Inspection
Connecting Rod and Crankshaft End Play Inspection
1. Remove the oil pump.
2. Remove the baffle plate.
3. Measure the connecting rod end play with a feeler gauge (A) between the connecting rod (B) and the crankshaft (C).
4. If the connecting rod end play is beyond the service limit, install a new connecting rod and recheck. If it is still beyond the service limit, replace the crankshaft Crankshaft and Piston Removal.
5. Push the crankshaft firmly away from the dial indicator by prying, and zero the dial against the end of the crankshaft. Then pull the crankshaft firmly back toward the indicator by prying; the dial reading should not exceed the service limit.