Trunk Lid Opener Main Switch Test/Replacement
Trunk Lid Opener Main Switch Test/Replacement
1. Remove the glove box housing Glove Box Removal / Installation.
2. Carefully push the main switch (A) out from behind the glove box housing.
3. Disconnect the 2P connector (B) from the main switch.
4. Check for continuity between terminals No. 1 and No. 2.
- With the main switch ON, there should be continuity.
- With the main switch OFF, there should be no continuity.
5. If the continuity is not as specified, replace the main switch.