Torque Converter Housing Countershaft Bearing Replacement
Torque Converter Housing Countershaft Bearing Replacement
Special Tools Required
- Adjustable Bearing Puller, 25-40 mm 07736-A01000B
- Driver Handle, 15 x 135L 07749-0010000
- Bearing Driver Attachment, 78 x 80 mm 07NAD-PX40100
1. Remove the countershaft bearing from the torque converter housing using the 25-40 mm adjustable bearing puller and a commercially available 3/8 "-16 slide hammer (A).
2. Install the ATF guide plate (A) into the torque converter housing, then install a new bearing (B) in the direction shown.
3. Install the bearing (A) in the torque converter housing using the driver handle and the 78 x 80 mm attachment; install the bearing outer notch-cut (B) to a depth (C) of 0-0.03 mm (0-0.001 in) below the torque converter housing surface (D).