Tightening Specifications
Connecting Rod Bolt Inspection
Measure the diameter of each connecting rod bolt at point A and point B.
Calculate the difference in diameter between point A and point B.
Point A-Point B = Difference in Diameter
Install a new bolt if the difference in diameter is out of specification.
Connecting Rod Bolts
First step Finger tight
Second step 41 Nm (4.2 kg-m, 30 lb-ft)
Final step Tighten an additional 120°