Advanced Diagnostics - DTC P0498: Evaporative Emission (EVAP) Canister Vent Shut Valve Circuit Low VoltageGeneral Description
The evaporative emission (EVAP) canister vent shut valve is attached to the EVAP canister to control the venting of the EVAP canister to atmosphere. The EVAP canister vent shut valve is open (open to atmosphere) when the VSV signal is OFF. If the return signal is "OFF" when the powertrain control module (PCM) outputs the "ON" signal to the EVAP canister vent shut valve, the PCM detects a malfunction and stores a DTC.
Monitor Execution, Sequence, Duration, DTC Type, OBD Status
Enable Conditions
Malfunction Threshold
The return signal is "OFF" for at least 5 seconds when the PCM outputs the "ON" signal to the EVAP canister vent shut valve.
Confirmation Procedure with the HDS
Do the EVAP CVS ON in the INSPECTION MENU with the HDS.
Diagnosis Details
Conditions for setting the DTC
When a malfunction is detected during the first drive cycle, a Pending DTC is stored in the PCM memory. If the malfunction returns in the next (second) drive cycle, the MIL comes on and a Confirmed DTC and the freeze data are stored.
Conditions for clearing the DTC
The MIL is cleared if the malfunction does not return in three consecutive trips in which the diagnostic runs. The MIL, the Pending DTC, the Confirmed DTC, and the freeze data can be cleared with the scan tool Clear command or by disconnecting the battery.