Tightening Specifications
Connecting Rod Bolts
Inspection
Measure bolt diameter at Point A and Point B.
Calculate difference in diameter between Point A and Point B.
Point A-Point B 0-0.1 mm (0-0.004 in)
Install a new bolt if the difference in diameter is out of tolerance.
Tightening Sequence
First step 20 Nm (2.0 kg-m, 15 lb-ft)
Final step Tighten 90°