Suspension Stroke Sensor Test (Headlight Leveling System)
Suspension Stroke Sensor Test
1. Remove the suspension stroke sensor Suspension Stroke Sensor Replacement (Headlight Leveling System).
2. Measure the resistance between suspension stroke sensor 3P connector terminals No. 1 and No. 3. There should be about 3.5-6.5 kOhms.
3. Measure the resistance between suspension stroke sensor 3P connector terminals No. 2 and No. 3 with the linkage (A) moved. There should be about 0.5-4.5 kOhms.
4. If the resistance is not as specified, replace the suspension stroke sensor Suspension Stroke Sensor Replacement (Headlight Leveling System).