Tightening Specifications
Connecting Rod Bolts
Inspection
Measure the diameter of each bolt at point A and point B
Calculate the difference in diameter between point A and point B
Point A-Point B = Difference in Diameter
Difference in diameter specification 0-0.1 mm (0-0.004 in)
If difference in diameter is out of specification, replace bolt
Tightening Sequence
First step 41 Nm (4.2 kg-m, 30 lb-ft)
Second step Tighten an additional 120°