Torque Converter Housing Countershaft Bearing Replacement
Torque Converter Housing Countershaft Bearing Replacement
Special Tools Required
- Adjustable Bearing Puller, 25-40 mm 07736-A01000B
- Driver Handle, 15 x 135L 07749-0010000
- Bearing Driver Attachment, 62 x 68 mm 07746-0010500
1. Remove the countershaft bearing using the 25-40 mm adjustable bearing puller and a commercially available 3/8 ''-16 slide hammer (A).
2. Remove the ATF guide plate (A), and check it for wear and damage. If the guide plate is worn or damaged, replace it.
3. Install the ATF guide plate in the torque converter housing, and install the countershaft bearing (B).
4. Install the countershaft bearing securely in the torque converter housing using the driver handle and the 62 x 68 mm bearing driver attachment.
5. Make sure that the bearing outer race notch-cut (A) is installed at a height of 0-0.05 mm (0-0.002 in) (B) above the torque converter housing surface (C). Do not install the countershaft bearing higher than 0.05 mm (0.002 in) above the torque converter housing surface.