Computer, Computer Connection; Checking; Computer Range Reading, Calibrating
Work Sequence:
Computer, checking
Work sequence
- switch ignition ON
- select all computer functions in sequence, pressing function selector switch (1) and bottom of switch (2) to select time display
If it is not possible to select all functions, - check function selector switch
- repeat test
If it still is not possible to select all functions, or if computer display is dim:
- remove instrument cluster. (Do not detach connectors)
- check printed circuit for day/night illumination as follows:
Connections:
- connect voltmeter between connections for day illumination (A)
- switch ignition ON
Specified value:
^ 12.0 V (approx.)
- connect voltmeter between connections for night illumination (B)
- switch headlights ON and turn dimmer to full bright position specified value:
^ 12.0 V (approx.)
If one of the specified readings is not attained, - repair break in wiring using current flow diagram
If specified readings are attained, - replace day/night illumination bulbs
Computer Connections at Hall Sender, Checking:
Computer connections at Hall sender, checking
Black wire (1) Green wire (2) Cruise control system connection (3)
14 Point Connector:
- turn ignition ON
- connect voltmeter between contacts 1 & 2, 1 & D and 1 & E of 14 point connector one after the other
Specified value:
^ 12.0 V
- connect voltmeter between contacts 2 & 10, 2 & C, 2 & D of 14 point connector one after the other
Specified value:
^ 12.0 V
Note
If one of specified reading is not obtained, - repair break in wiring or
- replace voltage stabilizer
If specified readings are obtained and no display appears, - replace computer base plate or
- inspect printed circuit for damage
Computer Range Reading, Calibrating:
Computer range reading, calibrating
Note
Calibrate the range reading only after performing the following repairs:
^ replacing sender for fuel gauge
^ replacing computer (when range reading defective)
Note
Calibrate range reading with full fuel tank.
- press reset button with ignition switched OFF and hold
- switch ignition ON
- release reset button
^ display: approx. 700-800
Adjust Range Reading with Allen Wrench:
- adjust range reading with Allen wrench (arrow)
Note
The range calibrating screw can be turned only 1/2 turn between stops
Specified value:
^ 750
If the specified value is not attained, - check fuel gauge
- repeat range calibration
If the specified value still is not attained, - replace computer module