Operation CHARM: Car repair manuals for everyone.

Power Door Locking System - R and R Procedures

86audi2

Applies To


4000S


1985/1986
Group


57
Subject

Door Lock - Power


Part Identifier N/A
Key Points

Power door locking system, bi-pressure pump, control/operating valves, removing/installing

A242b
Number

86-05

May 30, 1986



CAUTION

Before proceeding with repairs to electrical system, disconnect battery ground strap.
Bi-pressure pump, removing

Work sequence



Bi-pressure pump

- remove right side trim panel in trunk
- unbolt pump (arrow)
- pull off electrical connector
- pull off pressure hose
- remove pump with insulation
Bi-pressure pump, installing

Work sequence

- reinstall pressure hose
- reinstall electrical connector
- remount pump
- reinstall trim panel
- check system for proper function

Note

If bi-pressure pump has been replaced, the power operated door locks will only function after being operated several times.
Front door control/operating valve, removing

Work sequence

Note

Driver's door contains control valve. Rear lid and other doors have operating valves.



Control/operating valve

- remove door trim panel
- pull back plastic moisture barrier
- remove bolts (arrows)
- unhook connecting rod
- pull off pressure hose (R/S door only)
- remove electrical connector (driver's door only)
- remove control/operating valve
Front door control/operating valve, installing

Work sequence

- reinstall pressure hose
- rehook connecting rod
- reinstall electrical connector (if applicable)
- reinstall control/operating valve
- check plastic moisture barrier for damage, replace if necessary
- reinstall trim panel
- check system for proper function
Rear door operating valve, removing

Work sequence



Rear door operating valve

- remove door trim panel
- pull back plastic moisture barrier
- remove phillips head screws (arrows)
- unhook connecting rod
- pull off pressure hose
- remove operating valve
Rear door operating valve, installing

Work sequence

- reinstall pressure hose
- rehook connecting rod
- remount operating valve
- check plastic moisture barrier for damage, replace if necessary
- reinstall trim panel
- check system for proper function
Rear lid operating valve, removing

Work sequence




Rear lid operating valve

- remove phillips head screws (arrows)
- unhook connecting rod
- pull off pressure hose
- remove operating valve
Rear lid operating valve, installing Work sequence

- reinstall pressure hose
- rehook connecting rod
- remount operating valve
- check system for proper function

Note

When system is functioning properly, all locks must close within two seconds. If bi-pressure pump runs more than five seconds system has leak. Control valve in bi-pressure pump should shut off pump after 35 seconds.