Fan Control Module
To check the blower control unit:- Remove electrical connector from control head panel
- Turn ignition "ON".
- Check for power at terminal 1 of blower control unit.
- Check for ground at terminal 5 of blower control unit.
- Connect test light between terminals 1 and 6. (Do not use a jumper wire).
^ blower motor should run.
- Connect test light between terminals 5 and 6.
^ blower should not run. If blower runs, replace blower control.
- Remove connector from blower control unit and connect wires on connector from terminals 1 and 6 with jumper wire.
^ blower motor should run. If not, replace blower motor.
Terminal Function
1 12V (Terminal 15) with ignition on from fuse 17
3 Power output to blower
5 Ground
6 Input signal from control panel head used to activate and control blower motor speed. Voltage ranges from approximately 2 volts in LO fan speed to 6 volts in HI fan speed.