Fuel Pressure Regulator
AIR FLOW SENSOR POTENTIOMETERResistance between sensor terminals 1 & 2 5K ohms [1]
Resistance between sensor terminals 1 & 3 4K ohms [1]
[1] Sensor plate in rest position.
CARBON CANISTER SHUT-OFF VALVE
Resistance Approx. 30-60 ohms
COLD START VALVE
Resistance Approx. 10 ohms
COOLANT TEMPERATURE SENSOR
Resistance @ 20~C (68~F) Approx.2.5K ohms
Resistance @ 80~C (176~F) Approx. 200-300 ohms
DIFFERENTIAL PRESSURE REGULATOR
Resistance 17 - 22 ohms
Nominal current @ idle 0-5mA positive current
IDLE STABILIZER VALVE
Resistance 3-8 ohms
OXYGEN SENSOR
Voltage output @ operating temperature >300~C (575~F)
Range 0.1-1.0V
Nominal 0.3-0.6V
Heater voltage Battery voltage
Heater current 0.5 - 3.0A