A/C - Water from Air Vents/Moisture in Front Footwell
GROUP: 87NUMBER: 91-04
DATE: May 31, 1991
SUBJECT:
Water Spray From Air Vents And Moisture In Front Foot Well
MODEL(S):
80/90, V8 M.Y. 1990 - 1991
CONDITION:
A/C drain hose kinked or not fully seated on/in A/C evaporator housing. This condition may allow water to collect in evaporator housing and be forced out through vents or splash out into front foot wells.
PRODUCTION:
Change of lubrication allows easier assembly of drain hose on evaporator housing.
As of: February 1991
VIN: 8A_MA 190 350
8B_MA 008 387
4C_MN 002 713
SERVICE:
Check placement and seating of drain hose. Hose must be free of kinks, seated flush to bottom of evaporator housing, and have drain valve at bottom of hose. Valve must retain 1" of water in hose for proper function.