Evaporator Refrigerant Lines
- discharge A/C refrigerant system
- remove bolt -A-
- loosen refrigerant line clamp and remove lines from evaporator
- plug all open connections to prevent moisture and dirt contamination
- install in reverse order of removal noting the following:
- replace 0-ring seals -B- and -C-
^ O-ring seal -C- (inlet): 10.8 mm inside diameter, 1.8 mm thickness
^ O-ring seal -B- (outlet): 17.2 mm inside diameter, 1.8 mm thickness
- ensure lines fit into evaporator smoothly without binding
- torque bolt -A- to 15 Nm (11.0 ft lb)