Condenser Fan: Locations
Cooling Fan/Radiator Assembly
1 Coolant pipe
2 Connector
• For Engine Coolant Level (ECL) warning switch -F66- in expansion tank
3 Expansion tank
• With Engine Coolant Level (ECL) warning switch -F66-
4 Cap
5 10 Nm (7 ft lb)
6 Fan with viscous clutch
• "FRONT" marking on outer fan ring must point in direction of travel
• Switching temperature 76° ± 4°C (169° ± 39°F) ambient temperature at viscous clutch
• Tightening torque depends on tools used
• Right-hand thread
7 Fan frame
8 10 Nm (7 ft lb)
9 Coolant Fan Control (FC) thermo- switches -F18- and -F54-
• 25 Nm (18 ft lb)
• Switching temperatures:
1 =1st stage:
on at 92°-97°C (198°-207°F)
off at 84°-91°C (183°-196°F)
2 = 2nd stage:
on at 99°-105°C (210°-221°F)
off at 91°-98°C (196°-208°F)
+ = Battery Positive Voltage (B+)
10 10 Nm (7 ft lb)
11 Packing
12 Bonded rubber bushing
13 Left air guide
14 Radiator
15 Upper air guide
16 10 Nm (7 ft lb)
17 Angle bracket
18 Rubber grommet
• For angle bracket
19 Right air guide
20 Lower air guide
21 10 Nm (7 ft lb)
• Important: Left-hand thread
22 Lock washer
• Grabs into fan
• Bend over one tooth to lock nut
23 Fan
24 Washer
25 Coolant fan motor
26 10 Nm (7 ft lb)
27 Fan frame
• For electric coolant fan
28 10 Nm (7 ft lb)
29 Clip
• For wiring to coolant fan motor