Read Measuring Value Block (Function 08)
Automatic climate control
NOTE: Ten measuring value blocks with 4 measuring display fields each are used.
If printer is switched ON, display is automatically printed out.
- Before reading measuring value block, check Diagnostic Trouble Code (DTC) memory.
- Eliminate/repair all malfunctions, then erase DTC memory.
- Keep engine running after checking DTC memory.
- Operate VAG 1551 scan tool until display shows "AC/Heating Electronics" address word 08.
Indicated on display
Rapid data transfer HELP
Select function XX
NOTE: Press HELP button to print out list of available functions.
- Press buttons -0- and -8- to select "Read Measuring Value Block" function 08.
Indicated on display
Rapid data transfer Q
08 - Read Measuring Value Block
- Press -Q- button to confirm input.
Indicated on display
Read measuring value block HELP
Input display group number XXX
- Press buttons -0-, -0- and -1- to select display group 001.
- Press -Q- button to confirm input.
Indicated on display
Read measuring value block X
1 2 3 4
NOTE:
- For description of the 4 display fields in individual display groups See tables beginning below.
- Values marked with (*) were valid when OBD (On Board Diagnosis) "Rapid data transfer" was initiated.
- All display values NOT marked with (*) indicate current value.
To select another display group:
- Press C button.
Indicated on display
Read measuring value block HELP
Input display group number XXX
- Enter display group number.
- Press -Q- button to confirm input.
To test electrical inputs
- Connect VAG 1598 test box to A/C control head connectors using VAG 1598/11 and VAG 1598/12 adapter cables.
- For test box socket identification when using VAG 1598/11 adapter cable. VAG 1598 Test Box, Connecting
Description of display groups and display fields
Display group No. 001
1) Value when rapid data transfer was first initiated.
Display group No. 002
1) Value when rapid data transfer was first initiated.
Display group No. 003
1) Value when rapid data transfer was first initiated.
Display group No. 004 and 005
1) Value when rapid data transfer was first initiated.
Display group No. 006
1) Value when rapid data transfer was first initiated.
Display group No. 007
1) Value when rapid data transfer was first initiated.
Display group No. 008
1) Value when rapid data transfer was first initiated.
Display group No. 009
1) Value when rapid data transfer was first initiated.
Display group No. 010 (Part 1 of 2)
1) Value when rapid data transfer was first initiated.
Description of display group 001, display field 1 compressor switch-OFF conditions
Display group No. 010 (Part 2 of 2)
Display field 0 and 1
1) If display "5" or "6" appears in addition to this display, ignore "5" or "6".
Display field 2, 3, 4 and 5
1) If display "5" or "6" appears in addition to this display, ignore "5" or "6".
Display field 6, 7 and 8
1) If display "5" or "6" appears in addition to this display, ignore "5" or "6".
Display field 9, 10 and 11
1) If display "5" or "6" appears in addition to this display, ignore "5" or "6".
Display field 12, 13 and 14