Trip Computer, Range Calibration
Set range calibration ONLY after replacing the trip computer (printed circuit).NOTE: The trip computer calculates fuel consumption based on 10 litres/100 km regardless if the computer display is in US or metric measurement units.
- Switch ignition OFF.
- Remove connector (arrow) from fuel level sensor.
- Using jumper wires, connect tester VW 1301 to fuel level sensor connector as shown.
- Set tester VW 1301 to 250.
- Press and hold RESET button.
- Switch ignition ON.
- Release RESET button.
- Display must read approximately 80
If NOT:
- Adjust range calibration as follows:
CAUTION!
Range calibration screw can only be turned 1/2-turn between stops.
- Remove instrument cluster trim.
- Insert a small flat blade screwdriver (100 mm long, 2 mm blade diameter) and turn adjusting screw -A-.
- Recheck range calibration.