Diagnostic Channel 53 - Graphics Channel 2
Diagnostic Channel 53 - Graphics Channel 2
Active electrical outputs
Note
When an NO system electrical output is activated, a segment of the "88.8" display, noted below as an alpha-numeric code, will illuminate.
The decimal point in the "88.8" display will not illuminate in this channel.
a1 - Fan for interior temperature sensor
b1 - Fresh air/recirculation flap closed (recirculation mode)
c1 - Heater valve closed
d1 - Bi-directional wiring harness
e1 - A/C compressor ON
f1 - Coolant fan first speed ON
*g1 - System function OK
a2, b2 - Air flow flap open
c2 - Air flow flap closed
d2, e2 - Footwell/defroster flap in "footwell" position
f2 - Footwell/defroster flap in "defrost" position
*g2 - System function OK
a3, b3 - Central flap in "instrument panel outlet" position
c3 - Central flap in "footwell outlet/defrost" position
d3, e3 - Temperature flap in "cold air" position
f3 - Temperature flap in "warm air" position
*g3 - System function OK
* Segments g1, g2 and g3 must illuminate simultaneously to indicate system function is OK.