Test Step 1
Subject of test:
Voltage supply to ABS Control Module J104
Subject of test:
^ Ground connection to ABS Control Module J104
^ ABS Warning Light K47
^ Inlet/outlet valves in ABS
Hydraulic Unit N55 (resistance)
Note:
If one of the LEDs lights up weaker (from -1, -3 and 4.1 and 4.1 to 4.4), it indicates contact resistance.
Check related connectors and wiring according to wiring diagram.