Pre-Test Requirements
Required vehicle-specific technical information sources:^ Applicable wiring diagram.
^ Repair Manual, Groups 01, 44, 45, 47.
Testers required:
^ Scan Tool VAG 1551.
^ ABS tester VAG 1710 with adapter cable VAG 1710/1.
^ Digital multimeter Fluke 83 (US 1119).
^ Test box VAG 1598 and adapter harness VAG 1598/3.
^ Test lead set VW 1594.
Test requirements:
^ All tires at correct inflation pressure.
^ Correct tire size mounted, same tire size and tread pattern on all wheels.
^ Battery voltage (B+) greater than 10.5 V:
- indicator lamp for Generator K2 goes out after engine starts
- Generator V-belt OK and tensioned
^ Hydraulic connections of hydraulic unit and wheel brake cylinders not leaking.
^ Conventional vehicle brake system OK (brake pads, function, fluid level).
^ Ground connection of return flow pump OK (check for tight fit and corrosion).
^ Wheel bearings and wheel bearing play OK
^ Brake lights and Brake Light Switch OK.
^ Function of manually engaged differential lock OK - all wheel drive only. Rear Differential Lock Indicator Light K46 lights up after differential lock is engaged and goes out completely after differential lock is turned off.