Operation CHARM: Car repair manuals for everyone.

01N Transmissiom

Terminal Identification 68-pin TCM Harness Connector And VAG 1598/18 Test Box Sockets

1. Ground (GND) (terminal 31)
2. Not assigned
3. Not assigned
4. Not assigned
5. Not assigned
6. Transmission fluid temperature sensor -G93-
7. Not assigned
8. Not assigned
9. Solenoid valve 3 -N90-
10. Solenoid valve 7 -N94-
11. Park/neutral signal
12. Kick down for A/C
13. Ignition timing point influence
14. Not assigned
15. Brake light switch -F- signal voltage
16. Kick down switch -F8-
17. Not assigned
18. Multi-function trans. range switch -F125-
19. Engine speed signal
20. Vehicle Speed Sensor (VSS) -G68-
21. Transmission vehicle speed sensor -G38-
22. Solenoid valve 6 -N93- voltage supply
23. Battery Positive Voltage (B+) (terminal 15)
24. K-wire for On Board Diagnostic
25. Not assigned
26. Not assigned
27. Not assigned
28. Not assigned
29. Shift lock solenoid -N110-
30. Not assigned
31. Not assigned
32. Not assigned
33. Not assigned
34. Not assigned
35. Not assigned
36. Not assigned
37. Not assigned
38. Not assigned
39. Not assigned
40. Multi-function trans. range switch -F125-
41. Load signal (throttle value) from engine control module 1)
42. Not assigned
43. Vehicle Speed Sensor (VSS) -G68- (shielding)
44. Transmission vehicle speed sensor -G38- (shielding)
45. Battery Positive Voltage (B+) (terminal 30)
46. Not assigned
47. Not assigned
48. Not assigned
49. Not assigned
50. Not assigned
51. Not assigned
52. Not assigned
53. Not assigned
54. Solenoid valve 2 -N89-
55. Solenoid valve 1 -N88-
56. Solenoid valve 5 -N92-
57. Selector lever display
58. Solenoid valve 6 -N93-
59. Not assigned
60. Cruise control system (terminal 15 input)
61. Cruise control system (output)
62. Multi-function trans. range switch -F125-
63. Multi-function trans. range switch -F125-
64. Not assigned
65. Vehicle Speed Sensor (VSS) -G68-
66. Transmission vehicle speed sensor -G38-
67. Solenoid valve Battery Positive Voltage (B+)
68. Not assigned

1) Signal can only be checked using "Read Measuring Value Block" function 08.