Operation CHARM: Car repair manuals for everyone.

Read Measuring Value Block

When reading measuring value block in conjunction with "Checking function sequence", Repair Group 96, all input and output signals of the convertible top control module -J256- are scanned during convertible top movement.

Test requirements
- Electrical consumers switched off
- Ignition switched on
- Check and erase DTC memory.

Indicated on display

Rapid data transfer HELP
Select function XX


- Press buttons -0- and -8- to select "Read Measuring Value Block" function 08.

Indicated on display

Rapid data transfer Q
08 - Read Measuring Value Block


- Press -Q- button to confirm input.

Indicated on display

Read Measuring Value Block HELP
Input display group number XXX


- Select desired display group number.


NOTE: Display group 001 is used as an example to show the sequence.


- Press button -0- twice and button -1- to input display group 001.

Indicated on display

Read Measuring Value Block Q
Input display group number 001


- Press -Q- button to confirm input.

Indicated on display

Read Measuring Value Block 1
1 2 3 4



NOTES:
- For display groups 001 and 002 the display group number will be shown without the "00."
- Press -C- button before selecting additional display groups.
- With the printer switched on, the display shown is printed.
- Each time the PRINT button is pressed, the display shown is printed.
- Press -C- button.


Indicated on display

Read Measuring Value Block HELP
Input display group number XXX


- Enter appropriate display group number and press -Q- button to confirm input.

To end "Read Measuring Value Block" (function 08):
- Press -> button.

Indicated on display

Rapid data transfer HELP
Select function XXX


- Check and erase DTC memory.




Display group 001, display field 1 - switch status monitoring I




Display group 001, display field 2 - switch status monitoring II




Display group 001, display field 3




Display group 001, display field 4




Display group 002, display field 1





Display group 002, display field 2 - solenoids

NOTE: In display group 002, if a component is not connected, or if there is an open circuit in the wiring, a "1" is always displayed for the affected component.