Read Measuring Value Block
When reading measuring value block in conjunction with "Checking function sequence", Repair Group 96, all input and output signals of the convertible top control module -J256- are scanned during convertible top movement.Test requirements
- Electrical consumers switched off
- Ignition switched on
- Check and erase DTC memory.
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -8- to select "Read Measuring Value Block" function 08.
Indicated on display
Rapid data transfer Q
08 - Read Measuring Value Block
- Press -Q- button to confirm input.
Indicated on display
Read Measuring Value Block HELP
Input display group number XXX
- Select desired display group number.
NOTE: Display group 001 is used as an example to show the sequence.
- Press button -0- twice and button -1- to input display group 001.
Indicated on display
Read Measuring Value Block Q
Input display group number 001
- Press -Q- button to confirm input.
Indicated on display
Read Measuring Value Block 1
1 2 3 4
NOTES:
- For display groups 001 and 002 the display group number will be shown without the "00."
- Press -C- button before selecting additional display groups.
- With the printer switched on, the display shown is printed.
- Each time the PRINT button is pressed, the display shown is printed.
- Press -C- button.
Indicated on display
Read Measuring Value Block HELP
Input display group number XXX
- Enter appropriate display group number and press -Q- button to confirm input.
To end "Read Measuring Value Block" (function 08):
- Press -> button.
Indicated on display
Rapid data transfer HELP
Select function XXX
- Check and erase DTC memory.
Display group 001, display field 1 - switch status monitoring I
Display group 001, display field 2 - switch status monitoring II
Display group 001, display field 3
Display group 001, display field 4
Display group 002, display field 1
Display group 002, display field 2 - solenoids
NOTE: In display group 002, if a component is not connected, or if there is an open circuit in the wiring, a "1" is always displayed for the affected component.