Operation CHARM: Car repair manuals for everyone.

Read Measuring Block Value Overview




Read Measuring Value Block (Function 08)


NOTE:
- Display groups 000-045 and 099 are identical to the display groups 000-045 and 099 described with "Basic Setting" function 04.
- After "Basic Setting" function 04 is called up, the ECM initiates the operations described below. These operations are not carried out alter calling up "Read Measuring Value Block" function 08.


Operations after calling up "Basic Setting" function 04:
- Constant ignition timing point of 12° BTDC will be output in idle
- Digital idle speed control is blocked
- Evaporative Emissions (EVAP) canister purge regulator valve is closed
- A/C compressor is shut off
- EGR valve is closed
- No coolant temperature correction; fixed value 80 °C (176 °F)
- Learning values are relearned (idle and CO content are adjusted automatically)

- Connect VAG 1551 scan tool and operate until display shows "Select function XX".

Indicated on display


Rapid data transfer HELP
Select function XX



NOTE: After the HELP button is pressed, an overview of possible functions is printed out.


- Press buttons -0- and -8- to select "Read Measuring Value Block" function 08.


Indicated on display


Rapid data transfer HELP
08 - Read Measuring Value Block



- Press -Q- button to confirm input.

Indicated on display


Read measuring value block HELP
Input display group number XXX



NOTE: After the HELP button is pressed, the procedure for input of the display group number is printed out.


- Input desired display group number according to display group overview Basic Setting (Function 04)


NOTE: Display group number 001 is used as an example to show the input sequence.


- Push buttons -0-, -0- and -1- for display group number 001.

Indicated on display


Read measuring value block Q
Input display group number 001



- Press -Q- button to confirm input.

Display fields 1 through 4 are indicated on the display.


Read measuring value block 1
1 2 3 4



NOTE:
- To change to another display group, proceed as follows:







- The values in display fields 1 through 10 are shown in decimal form in display group 000.
- The current 3-digit display group number is shown without the first zero. In display groups 000 to 009, the number is shown without the first two zeroes.
- When the printer is switched on, the current display is printed on the paper strip.
- Every time the PRINT button is pressed, the current display is printed out again.


- If the specified values are obtained in all display fields, press -> button.

Indicated on display


Rapid data transfer HELP
Select function XX



- Press buttons -0- and -6- to select "End Output" function 06.

Indicated on display


Rapid data transfer Q
06 - End output



- Press -Q- button to confirm input.

Indicated on display


Rapid data transfer HELP
Insert address word XX