Fig. 17 Checking Synchronizer Ring For Wear
Fig. 17 Checking synchronizer ring for wear
- Press synchronizer-ring into operating sleeve and measure gap -a- using feeler gauge at positions -A-, -Band -C-.
- Add calculated measurements and divide by 3.
The average gap must not be less than 0.5 mm (0.019 inch).