Channel 07 (Inspection 1 Service Interval Value - Time/Days)
SRI, inspection indicator (In 1), resetting (time)
Initiate Adaption Function. Adaptation Function Initiation
- Press button -0- and -7- to select channel 7.
- Press -Q- button to confirm input.
Channel 7 Adaptation 36 ->
<-13->
- Advance through program sequence with button ->.
Channel 7 Adaptation 36 Q
Input adaptation value XXXXX
- Enter adaptation value between 0 days (00000) and 360 days (00036). The value can be entered in steps of 10 days. Example: 360 days ,therefore enter 00036.
- Press -Q- button to confirm input.
Channel 7 Adaptation 36 Q
<-13->
- Press -Q- button to confirm input.
Channel 7 Adaptation 36 Q
Store changed value?
- Press -Q- button to confirm input.
Channel 7 Adaptation 36 ->
Changed value is stored
- Press -> button to end coding.
Rapid data transfer HELP
Select function XX
- Press buttons -1- and -0- to select "Adaptation" function 10.
Rapid data transfer Q
10 - Adaptation
- Press -Q- button to confirm input.
Adaptation
Insert channel number XX