Initiating Central Locking System Coding
Indicated on displayRapid data transfer HELP
Select function XX
- Press buttons -0- and -7- to select "Code Control Module" function 07.
- Press -Q- button to confirm input.
Indicated on display
Code control module
Enter code number XXXXX (0-32000)
- Enter a valid 5-digit code using buttons (for example 03228).
NOTE: Determine the valid coding for the current central locking system pump using the standard coding table Read Measuring Value Block (Function 08) or the answers for individual coding. Read Measuring Value Block (Function 08)
- Indicated on display
Code Control Module Q
Input code number 03228 (0-32000)
- Press -Q- button to confirm input.
Indicated on display
8L0862257A CV-Pump, Alarm ->
Coding 03228 WSC 06812
- End coding procedure by pressing -> button.
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -6- to select "End Output" function 06.
Indicated on display
Rapid data transfer Q
06 - End Output
- Press -Q- button to confirm input.
NOTE: "Read Measuring Value Block" function O8 can be used to check the central locking system pump coding in display group 004. Read Measuring Value Block (Function 08)