Work Procedure
Work ProcedureA. Audi A4
Connector Modification
^ Bring vehicle into service facility
^ Open rear seat ashtray cover-i-
^ Remove ashtray -4-
^ Remove OBD II DLC cover -2- in direction of arrow
^ Protect Data Link Connectors with tape to avoid entrance of shavings
^ Use small screwdriver -3-; push down on connectors at points indicated by arrows, at the same time push adapter downwards (may have to wiggle adapter slightly)
^ Release plug by pressing downwards
^ Attach supplied template -5- from tool kit, US 9206
^ Use reamer -7- from tool kit US 9206 and insert into drill -6-
^ Carefully ream inside interface adapter housing, starting at point "A", moving to "B" and continuing to "C". Remove overlapping plastic material (Do not shave metal)
^ Remove reamer and template
^ Thoroughly vacuum shavings
^ Press adapter upward and lock into position
^ Reinstall ashtray and cover
B. Check/lnstall OBD II Label (A4)
^ Check if OBD II Data Link Connector location label is present underneath steering column
^ If not, affix supplied OBD II label, after area has been cleaned
C. Audi Cabriolet
Replace OBD II DLC Bracket
^ Bring vehicle into service facility
^ Open rear ashtray cover -1-
^ Remove ashtray
^ Remove adapter bracket screw -3-
^ Lift rear of console -5- to remove bracket with adapter -4-
^ Disconnect adapter from bracket
^ Use new bracket, part number 8G0 972 633 A and connect to adapter
^ Reinstall in reverse order
D. Check/lnstall OBD II Label (Cabriolet)
^ Check if OBD II Data Link Connector location label is present underneath steering column
^ If not, affix supplied OBD II label after area has been cleaned